Camera interfaces
Manta Hardware Installation Guide V4.1.0
48
MANTA input description
MANTA input block diagram
(not: Manta G-145-30fps/201-30fps)
The inputs can be connected directly to +3.3 V and 5 V systems. If a voltage
higher than 6.0 V is used, an external resistor must be placed in series.
Figure 26: MANTA input block diagram
Used input voltage (U
inVCC
) External series resistor
2.5 V ... 6.0 V none
6.0 V ... 14.0 V 680
14.0 V ... 30.0 V 1.5 k
Table 7: MANTA: external resistors for different voltages
Parameter Value
U
in
(low) 0 V ... 0.8 V
U
in
(high) 2.5 V ... 6.0 V
Current 4 mA ... 17 mA
depends on input voltage
Flux voltage of the LED (@ 10 mA) 1.15 V typical
Table 8: MANTA input parameters
GPIn1
InGND
extern intern
GPIn2
330R
330R